A full charge takes 10.4 hours on a proper Level 2 setup. That timeline easily covers an overnight turnaround for your daily driving needs. Plugging into a standard household wall outlet takes 83 hours, which makes Level 2 mandatory.
The numbers
| Maximum AC charging rate | 11.5 kW (48 A) |
|---|---|
| Charger size to buy | 48 A |
| Circuit breaker required | 60 A |
| Outlet / connection | hardwired (a 48 A EVSE must be hardwired -- no household receptacle is rated for it) |
| Charge port | J1772 |
| Full charge on Level 2 | about 10.4 hours |
| Range added per hour (Level 2) | about 31 miles |
| Full charge on a 120 V outlet | about 83 hours |
| Range added per hour (120 V) | about 3.9 miles |
| EPA rated range | 326 miles |
| Energy for a full charge | about 120.0 kWh at the wall |
Why 48 amps and not more
Your car accepts a maximum draw of 48 amps. Buying a smaller charger means slower speeds and wasted time. The battery holds 120.0 kWh of energy. A 48-amp supply pushes 31 miles of range into the pack every hour. Pumping more current into the vehicle will not speed up the charge because the onboard charger maxes out at 11.5 kW.
What the install involves
You need a 60-amp breaker to supply the 48-amp EVSE safely. No household receptacle handles this continuous load, so your charging unit must be hardwired directly. Call a licensed sparky to pull the heavy copper wire, land it on the new breaker, and verify your main panel has the spare capacity. Skipping these safety steps risks thermal damage to your home wiring.
Chargers that match this car
Energy monitoring built in. Hardwire it for the full 48 A.
Compact unit, good for tight garages.
Adjustable from 16 A to 50 A in the app, which helps if your panel is tight.
Worth having as well
Common questions
- What connector does this vehicle use?
- The car uses a J1772 connector. Many units ship with a NACS port and include a J1772 adapter, so a standard J1772 home charger still works. Confirm your port type before ordering equipment.
- Can I use a normal wall outlet?
- You can plug into a standard household outlet for Level 1 charging, but it delivers only 3.9 miles of range per hour. Filling the battery this way takes 83 hours. You need a dedicated Level 2 circuit for practical daily use.
- Why does the EPA charge time differ from the maximum rate?
- The EPA test estimates an 11.2 hour charge time at 29 miles per hour because standardized testing conditions vary. Your actual vehicle hits 10.4 hours and 31 miles per hour when running at its peak onboard AC rate.
- Do I need a special adapter for Tesla chargers?
- You can use a Tesla to J1772 adapter like the Lectron unit to plug into Tesla Destination Chargers and Wall Connectors. This gives you more options when you travel away from home.