BuyWhatFits

GE breaker for an EV charger

The breaker
THQL2150GFT or THQL2160
The THQL2150GFT is a 50 A GFCI breaker for a 40 A charger on a 14-50 outlet. The THQL2160 is a standard 60 A breaker for a 48 A charger, hardwired.

These fit GE panels for type THQL. The label inside the panel door names the maker and lists the breakers the panel accepts, so check it first. GE home panels take type THQL breakers, 1 inch wide per pole. GE's breaker line now belongs to ABB, whose catalog carries the same part numbers.

By charger

A charger may draw 80% of its breaker's rating, so each charger setting needs the breaker below. A charger that plugs into an outlet needs the GFCI version; a hardwired one usually takes the standard version.

Charger set toBreakerand wireCopper wirePlugs into an outletHardwired
16 A20 A12 AWG12 AWG THQL2120GFT
a 6-20 outlet
THQL2120
24 A30 A10 AWG10 AWG THQL2130GFT
a 14-30 or 6-30 outlet
THQL2130
32 A40 A8 AWG8 AWG THQL2140GFT
a 6-50 or 14-50 outlet on a 40 A circuit
THQL2140
40 A50 A8 AWG, or 6 AWG NM cable8 AWG, or 6 AWG NM cable THQL2150GFT
a 14-50 or 6-50 outlet
THQL2150
48 A60 A6 AWG, or 4 AWG NM cable6 AWG, or 4 AWG NM cable No common outlet; hardwire it THQL2160

Every breaker here is two-pole, 120/240 V. Wire sizes are from NEC Table 310.16: the 75°C column for wire in conduit and the 60°C column for NM cable. A long run may need a size larger.

Outlet or hardwired

Before buying

Where to buy

The links search Amazon for each part number. Check that the listing shows the same number before buying.

For a charger that plugs into an outlet

GE THQL2150GFT50 A · GE panels for type THQL · 14-50 or 6-50 outlet50 A two-pole GFCI, self-testing, with a pigtail neutral View on Amazon
GE THQL2140GFT40 A · GE panels for type THQL · 14-50 or 6-50 outlet, 40 A circuit40 A two-pole GFCI, self-testing, with a pigtail neutral View on Amazon
GE THQL2130GFT30 A · GE panels for type THQL · 14-30 or 6-30 outlet30 A two-pole GFCI, self-testing, with a pigtail neutral View on Amazon
GE THQL2120GFT20 A · GE panels for type THQL · 6-20 outlet20 A two-pole GFCI, self-testing, with a pigtail neutral View on Amazon

For a hardwired charger

GE THQL216060 A · GE panels for type THQL · Hardwired charger60 A two-pole, standard View on Amazon
GE THQL215050 A · GE panels for type THQL · Hardwired charger50 A two-pole, standard View on Amazon
GE THQL214040 A · GE panels for type THQL · Hardwired charger40 A two-pole, standard View on Amazon
GE THQL213030 A · GE panels for type THQL · Hardwired charger30 A two-pole, standard View on Amazon

A charger for the 14-50 outlet

Grizzl-E Classic 40A40 A · J1772 · plug-inRugged metal enclosure, built for outdoor use. Can be set to 16, 24, 32 or 40 A inside the unit. Breaker and settings View on Amazon
ChargePoint Home Flex NEMA 14-5040 A · J1772 · plug-inPlugs into an existing 14-50 outlet, no hardwiring. Breaker and settings View on Amazon

A 48 A charger for the 60 A circuit

Wallbox Pulsar Plus 48A48 A · J1772 · hardwiredCompact unit, good for tight garages. Breaker and settings View on Amazon
Tesla Wall Connector48 A · NACS · hardwiredTesla's own unit. Native NACS, hardwire only. Breaker and settings View on Amazon

As an Amazon Associate we earn from qualifying purchases.

Common questions

What breaker does a 14-50 outlet need in a GE panel?
A THQL2150GFT: 50 A, two-pole, with GFCI protection, which section 625.54 of the 2020 and 2023 National Electrical Code requires for a new outlet for EV charging. Wire it with 8 AWG copper wire in conduit or 6 AWG NM cable. It suits a charger set to 40 A.
What breaker does a 48 A charger need in a GE panel?
A THQL2160, a standard 60 A two-pole breaker, with 6 AWG copper wire in conduit or 4 AWG NM cable. A charger is a continuous load, so the breaker is rated at 125% of its current. A 48 A charger has to be hardwired, since a 60 A circuit has no common outlet.
Which GE panels take these breakers?
GE load centers whose label lists type THQL breakers, which covers most GE home panels. ABB, which now owns GE's breaker line, sells them under the same numbers.
Does a hardwired charger need a GFCI breaker?
Usually not. The GFCI rule in section 625.54 covers outlets, and most hardwired chargers have ground-fault protection built in, as Tesla's Wall Connector manual lists for that unit. Outdoors, section 210.8(F) can call for one on a circuit of 50 A or less, so the electrician and the local inspector have the final word.

Other panels

To size the circuit from the car, see breaker and wire size and the chargers compared.

Part numbers are from ABB's THQL2130GFT page, THQL2160 page, Gexpro's THQL2140GFT listing and the rest of the maker's catalog. Code references are to the National Electrical Code. Local rules differ, so have a licensed electrician confirm the breaker and wire before work starts. Updated November 13, 2026.