Which breaker for an EV charger, by panel
The size comes from the charger; the part number comes from the panel. Each panel line below has its own page with every size from 20 A to 60 A, the GFCI version for an outlet, and the wire.
| Panel | Per pole | 14-50 outlet, 40 A charger | Hardwired, 48 A charger |
|---|---|---|---|
| Square D Homeline | 1 inch | HOM250GFI | HOM260 |
| Square D QO | 3/4 inch | QO250GFI | QO260 |
| Eaton BR | 1 inch | GFTCB250 | BR260 |
| Eaton CH | 3/4 inch | CH250GFT | CHP260 |
| Siemens | 1 inch | QF250A | Q260 |
| GE | 1 inch | THQL2150GFT | THQL2160 |
The 14-50 column is a 50 A two-pole GFCI breaker; the hardwired column is a standard 60 A two-pole breaker.
Which panel you have
The label inside the panel door names the maker and lists the breaker types the panel accepts. Makers with two lines make them in different widths, and the lines do not interchange: Square D's Homeline is 1 inch per pole and its QO 3/4 inch, and Eaton's BR is 1 inch and its CH 3/4 inch.
Size by charger
| Charger set to | Breaker | Copper wire | Outlet |
|---|---|---|---|
| 16 A | 20 A | 12 AWG | a 6-20 outlet |
| 24 A | 30 A | 10 AWG | a 14-30 or 6-30 outlet |
| 32 A | 40 A | 8 AWG | a 6-50 or 14-50 outlet on a 40 A circuit |
| 40 A | 50 A | 8 AWG, or 6 AWG NM cable | a 14-50 or 6-50 outlet |
| 48 A | 60 A | 6 AWG, or 4 AWG NM cable | No common outlet; hardwire it |
A charger is a continuous load, so its breaker is rated at 125% of its current (NEC 625.41). Wire sizes are from NEC Table 310.16: the 75°C column in conduit and the 60°C column for NM cable.
GFCI or standard
An outlet installed for EV charging needs ground-fault protection under section 625.54 of the 2020 and 2023 code, and at 240 V that means a GFCI breaker. A hardwired charger usually goes on a standard breaker, since most have ground-fault protection built in. The outlet or hardwired guide weighs the two.
Where to buy
The links search Amazon for each part number. Check that the listing shows the same number before buying.
50 A GFCI, for a 14-50 outlet
| Square D HOM250GFI50 A · Homeline panels · 14-50 or 6-50 outlet50 A two-pole GFCI, Class A, 6 mA, with a pigtail neutral | View on Amazon |
| Square D QO250GFI50 A · QO panels · 14-50 or 6-50 outlet50 A two-pole GFCI, Class A, 6 mA, with a pigtail neutral | View on Amazon |
| Eaton GFTCB25050 A · Eaton BR panels · 14-50 or 6-50 outlet50 A two-pole GFCI, self-testing, with a pigtail neutral | View on Amazon |
| Eaton CH250GFT50 A · Eaton CH panels · 14-50 or 6-50 outlet50 A two-pole GFCI, self-testing, with a pigtail neutral | View on Amazon |
| Siemens QF250A50 A · Siemens panels for type QP · 14-50 or 6-50 outlet50 A two-pole GFCI, Class A, 5 mA, with a pigtail neutral | View on Amazon |
| GE THQL2150GFT50 A · GE panels for type THQL · 14-50 or 6-50 outlet50 A two-pole GFCI, self-testing, with a pigtail neutral | View on Amazon |
60 A, for a 48 A hardwired charger
| Square D HOM26060 A · Homeline panels · Hardwired charger60 A two-pole, standard | View on Amazon |
| Square D QO26060 A · QO panels · Hardwired charger60 A two-pole, standard | View on Amazon |
| Eaton BR26060 A · Eaton BR panels · Hardwired charger60 A two-pole, standard | View on Amazon |
| Eaton CHP26060 A · Eaton CH panels · Hardwired charger60 A two-pole, standard. Eaton's 60 A CH breaker is the CHP260; the CHF line stops at 50 A. | View on Amazon |
| Siemens Q26060 A · Siemens panels for type QP · Hardwired charger60 A two-pole, standard | View on Amazon |
| GE THQL216060 A · GE panels for type THQL · Hardwired charger60 A two-pole, standard | View on Amazon |
As an Amazon Associate we earn from qualifying purchases.
To pick the charger first, see the chargers compared and breaker and wire size.
Part numbers are from each maker's own catalog, linked on each panel's page. Have a licensed electrician confirm the breaker and wire before work starts. Updated November 13, 2026.