BuyWhatFits

Which generator interlock kit fits your panel

An interlock lets a portable generator feed the house through the panel, with the main breaker locked off while it does. The kit comes from the panel line and its main breaker; each line below has its own page with the kit for each main, the generator breaker, and the inlet and cord.

PanelKitGenerator breaker, 30 A50 A
Square D HomelineHOMCRBGK1C, HOMCGK2CHOM230HOM250
Square D QOQOCRBGK1C, QOCGK2CQO230QO250
Eaton BRBRMIKBR, BRMIKCSR, BRPMIKBR, BRPMIKCSRBR230BR250
Eaton CHCHMIKCSR, CHPMIKCH, CHPMIKCSRCHF230CHF250
SiemensECSBPK03, ECSBPK01, ECSBPK02Q230Q250
GETHQLLX1THQL2130THQL2150

Where a line has more than one kit, the main breaker decides; each page says which.

What an interlock does

Section 702.5 of the National Electrical Code requires transfer equipment for a generator that feeds a house, so it cannot send power back into the utility's lines, where it could hurt a line worker. An interlock is the simplest kind: a plate on the panel's cover that lets either the main breaker or the generator breaker be on, never both. The generator plugs into an inlet on the outside wall, and the house's own breakers pick which circuits run.

Sizing by generator

Generator outletUp toBreakerCopper wireInletCord
L14-307,200 W30 A two-pole10 AWGL14-30 inletL14-30P to L14-30R
14-50 or CS636912,000 W50 A two-pole8 AWG, or 6 AWG NM cableCS6375 inlet14-50P or CS6364 to CS6365

Watts are the outlet's limit at 240 V. Wire sizes are from NEC Table 310.16. The breaker fed from the generator needs a hold-down under section 408.36(D).

Generators and EV chargers

A charger set to 40 A draws 9,600 W, more than a 30 A generator outlet supplies, so switch the charger's breaker off while on generator power. The breaker part numbers by panel cover the charger's own circuit.

Where to buy

The links search Amazon for each part number. Check that the listing shows the same number before buying.

Interlock kits

Square D HOMCRBGK1C100 to 125 A · Homeline panels of 100 A and 125 A · Interlock kitQOM1 main breaker. Series S panels, indoor or outdoor View on Amazon
Square D HOMCGK2C150 to 225 A · Homeline panels of 150 A to 225 A · Interlock kitQOM2 main breaker. Series S indoor or Series S1 outdoor panels View on Amazon
Square D QOCRBGK1C100 to 125 A · QO panels of 100 A and 125 A · Interlock kitQOM1 main breaker. Series G or S indoor, or G, S1, S2 or S6 outdoor panels View on Amazon
Square D QOCGK2C150 to 225 A · QO panels of 150 A to 225 A · Interlock kitQOM2 main breaker. Series G or S indoor, or G or S1 outdoor panels View on Amazon
Eaton BRMIKBRSee label · BR panels with a backfed main · Interlock kitBackfed BR main breaker. Standard neutral bar View on Amazon
Eaton BRMIKCSRSee label · BR panels with a CSR main · Interlock kitCSR main breaker. Standard neutral bar View on Amazon
Eaton BRPMIKBRSee label · BR plug-on neutral panels with a backfed main · Interlock kitBackfed BR main breaker. Plug-on neutral rail View on Amazon
Eaton BRPMIKCSRUp to 225 A · BR plug-on neutral panels with a CSR main · Interlock kitCSR main breaker. Plug-on neutral rail View on Amazon
Eaton CHMIKCSRUp to 225 A · CH panels with a CSR or CSH main · Interlock kitCSR or CSH main breaker. Standard neutral bar View on Amazon
Eaton CHPMIKCH125 A · CH plug-on neutral panels with a backfed main · Interlock kitBackfed CH main breaker. Plug-on neutral rail View on Amazon
Eaton CHPMIKCSRUp to 225 A · CH plug-on neutral panels with a CSR main · Interlock kitCSR main breaker. Plug-on neutral rail View on Amazon
Siemens ECSBPK03150 to 225 A · Siemens Ultimate and Murray Rock Solid panels, 150 A and up · Interlock kitMBK150A, MBK200A or MBK225A main breaker. The generator breaker is a standard type QP, not AFCI, GFCI, three-pole or half-inch; not for 125 A panels with four spaces View on Amazon
Siemens ECSBPK01Up to 225 A · Siemens panels and meter combinations with the two breakers opposite · Interlock kitTwo-pole main across from the generator breaker. For a main that faces the generator breaker across the panel View on Amazon
Siemens ECSBPK02Up to 225 A · Siemens panels and meter combinations with the two breakers side by side · Interlock kitTwo- or four-pole main beside the generator breaker. For a main with the generator breaker next to it View on Amazon
GE THQLLX1150 to 225 A · GE PowerMark Gold Model 6 panels of 150 A to 225 A · Interlock kitFour-pole main breaker. The generator breaker goes in positions 2 and 4; the retainer is included View on Amazon

Inlet and cord

L14-30 power inlet box30 A · Any panel · Outside wallTakes the cord from a generator with an L14-30 outlet View on Amazon
L14-30 generator cord30 A · Any panel · Generator to inletL14-30P plug to L14-30R connector View on Amazon
CS6375 50 amp power inlet box50 A · Any panel · Outside wallTakes the cord from a generator with a 50 A outlet View on Amazon
CS6364 to CS6365 50 amp generator cord50 A · Any panel · Generator to inletFor a generator with a CS6369 outlet View on Amazon
14-50P to CS6365 50 amp generator cord50 A · Any panel · Generator to inletFor a generator with a 14-50 outlet View on Amazon

As an Amazon Associate we earn from qualifying purchases.

Kit numbers are from Square D's FAQs, GE's instructions and authorized distributors' listings, linked on each panel's page. Local rules differ, so have a licensed electrician confirm the kit before work starts. Updated November 13, 2026.