BuyWhatFits

Eaton BR generator interlock kit

The kit
BRMIKBR, BRMIKCSR, BRPMIKBR or BRPMIKCSR
The kit depends on the main breaker. The generator breaker is a BR230 for a 30 A generator or a BR250 for a 50 A one.

An interlock is a plate on the panel's cover that lets either the main breaker or the generator breaker be on, never both, so a portable generator can feed the house without sending power back into the utility's lines. Each kit is made for one panel line and one kind of main breaker. The label inside the panel door names the maker and the panel's catalog number, and the main breaker's type is printed on the breaker itself. BR breakers are 1 inch wide per pole. Eaton's other line, CH, is narrower, and the two do not interchange. An older panel may carry the Cutler-Hammer name, which Eaton owns.

By main breaker

KitMain breakerFits
BRMIKBRBackfed BR main breakerBR panels with a backfed main
Standard neutral bar
BRMIKCSRCSR main breakerBR panels with a CSR main
Standard neutral bar
BRPMIKBRBackfed BR main breakerBR plug-on neutral panels with a backfed main
Plug-on neutral rail
BRPMIKCSRCSR main breakerBR plug-on neutral panels with a CSR main
Plug-on neutral rail

Two things pick the kit: the main breaker's type, printed on it, and whether the panel has a plug-on neutral rail, which Eaton's label calls PON.

Generator breaker, inlet and cord

The generator breaker is a standard two-pole breaker from the panel's own line, fed backward from the generator. Its size follows the generator's 240 V outlet.

Generator outletUp toBreakerCopper wireInletCord
L14-307,200 WBR230
30 A
10 AWGL14-30 inletL14-30P to L14-30R
14-50 or CS636912,000 WBR250
50 A
8 AWG, or 6 AWG NM cableCS6375 inlet14-50P or CS6364 to CS6365

Watts are the outlet's limit at 240 V; the generator's own running rating may be lower. Wire sizes are from NEC Table 310.16: the 75°C column for wire in conduit and the 60°C column for NM cable.

Before buying

Where to buy

The links search Amazon for each part number. Check that the listing shows the same number before buying.

The interlock kit

Eaton BRMIKBRSee label · BR panels with a backfed main · Interlock kitBackfed BR main breaker. Standard neutral bar View on Amazon
Eaton BRMIKCSRSee label · BR panels with a CSR main · Interlock kitCSR main breaker. Standard neutral bar View on Amazon
Eaton BRPMIKBRSee label · BR plug-on neutral panels with a backfed main · Interlock kitBackfed BR main breaker. Plug-on neutral rail View on Amazon
Eaton BRPMIKCSRUp to 225 A · BR plug-on neutral panels with a CSR main · Interlock kitCSR main breaker. Plug-on neutral rail View on Amazon

The generator breaker

Eaton BR23030 A · Eaton BR panels · Generator with an L14-30 outlet30 A two-pole, backfed as the generator breaker; needs a hold-down View on Amazon
Eaton BR25050 A · Eaton BR panels · Generator with a 14-50 or CS6369 outlet50 A two-pole, backfed as the generator breaker; needs a hold-down View on Amazon

Inlet and cord

L14-30 power inlet box30 A · Any panel · Outside wallTakes the cord from a generator with an L14-30 outlet View on Amazon
L14-30 generator cord30 A · Any panel · Generator to inletL14-30P plug to L14-30R connector View on Amazon
CS6375 50 amp power inlet box50 A · Any panel · Outside wallTakes the cord from a generator with a 50 A outlet View on Amazon
CS6364 to CS6365 50 amp generator cord50 A · Any panel · Generator to inletFor a generator with a CS6369 outlet View on Amazon
14-50P to CS6365 50 amp generator cord50 A · Any panel · Generator to inletFor a generator with a 14-50 outlet View on Amazon

Other makers' kits

Generator interlock kit for Eaton BRSee listing · Eaton BR panels · Interlock kitPlates from other makers, each for named panel models. Check that the listing names the catalog number on your panel's label View on Amazon

As an Amazon Associate we earn from qualifying purchases.

Common questions

Which generator interlock kit fits an Eaton BR panel?
It depends on the main breaker: the BRMIKBR for BR panels with a backfed main (backfed BR main breaker); the BRMIKCSR for BR panels with a CSR main (CSR main breaker); the BRPMIKBR for BR plug-on neutral panels with a backfed main (backfed BR main breaker); the BRPMIKCSR for BR plug-on neutral panels with a CSR main (CSR main breaker). Two things pick the kit: the main breaker's type, printed on it, and whether the panel has a plug-on neutral rail, which Eaton's label calls PON. The kit has to be one the panel is listed for.
What is the generator breaker in an Eaton BR panel?
A BR230 for a generator with an L14-30 outlet, wired with 10 AWG copper wire, or a BR250 for one with a 14-50 or CS6369 outlet, wired with 8 AWG copper wire in conduit or 6 AWG NM cable. It is fed from the generator rather than the panel, so section 408.36(D) of the National Electrical Code requires a hold-down that keeps it from being pulled off.
Is a generator interlock kit up to code?
Yes, when it is listed for the panel. Section 702.5 of the National Electrical Code requires transfer equipment for a generator that feeds a house, so it cannot send power back into the utility's lines, and an interlock does that by keeping the main and generator breakers from being on together. Most places require a permit, and some inspectors accept only the panel maker's kit.
Can a portable generator run an EV charger through an interlock?
Rarely. A charger set to 40 A draws 9,600 W, more than an L14-30 generator outlet supplies (7,200 W), and most of what a 50 A outlet supplies (12,000 W) before the house's own loads. Switch the charger's breaker off while on generator power, or turn the charger's current down if the generator has room to spare.

Other panels

Kit numbers are from Eaton's BRPMIKCSR page and Eaton's BR interlock kit sheet. Code references are to the National Electrical Code. Local rules differ, so have a licensed electrician confirm the kit, breaker and wire before work starts. Updated November 13, 2026.